Hi Jerry-

Marks system Glinda a dec5000 m25 was having problems
yesterday.  I checked on it and found that it was having
a problem with one or more simms.  The error message didn't
correspond with slot numbers so I held off from swapping 
simms and placed a service call to Dec.  Bill M came in
today and checked system and found that it has 3rd party
mem simms (kingston?), also the system S/N is not in
Dec DB as being under contact.  Being under contract is
not an issue but the 3rd party simms are, because they
are not supported by Dec.

So basically what are we to do about Marks system?