[171434] in Hotline Meeting
Postponed - Bldg. 24 - All Normal Building Power 208V/120V Shutdown
daemon@ATHENA.MIT.EDU (Jennifer Garland)
Mon Aug 12 13:55:24 2013
From: Jennifer Garland <jennygar@plant.mit.edu>
To: "swade@mit.edu" <swade@mit.edu>, "craigp@MIT.EDU" <craigp@mit.edu>,
"sbleeb@mit.edu" <sbleeb@mit.edu>, "ramsay@mit.edu" <ramsay@mit.edu>,
"hbsweet@mit.edu" <hbsweet@mit.edu>,
OPS RM Campus Services Main
<rm-mcs@mit.edu>,
"opsnote@mit.edu" <opsnote@mit.edu>, "elk@MIT.EDU"
<elk@mit.edu>,
"diadiuk@mit.edu" <diadiuk@mit.edu>,
"mcgrath@mtl.mit.edu"
<mcgrath@mtl.mit.edu>,
"pbrenton@MIT.EDU" <pbrenton@mit.edu>,
"censabel@MIT.EDU" <censabel@mit.edu>,
"khewitt@mit.edu" <khewitt@mit.edu>, "elsye@MIT.EDU" <elsye@mit.edu>,
"cubstead@MIT.EDU" <cubstead@mit.edu>,
"cmodica@mit.edu" <cmodica@mit.edu>,
MIT Schedules Office
<schedules@mit.edu>,
"jdaley@nano.mit.edu" <jdaley@nano.mit.edu>,
"mondol@mit.edu" <mondol@mit.edu>,
"heatherg@mit.edu" <heatherg@mit.edu>,
"shutdowns@mit.edu" <shutdowns@mit.edu>,
"whomeyer@mit.edu"
<whomeyer@mit.edu>,
"ksemerj@mit.edu" <ksemerj@mit.edu>,
Steven Gilligan
<sgilliga@plant.mit.edu>,
"garysaffie@plant.mit.edu"
<garysaffie@plant.mit.edu>
Date: Mon, 12 Aug 2013 13:55:18 -0400
Message-ID: <4EEA516695C10541B7CB963FF54A56AF13C69DDE2A@dof-exchmbx01.facilities.ms.mit.edu>
Content-Language: en-US
Content-Type: multipart/alternative;
boundary="_000_4EEA516695C10541B7CB963FF54A56AF13C69DDE2Adofexchmbx01f_"
MIME-Version: 1.0
--_000_4EEA516695C10541B7CB963FF54A56AF13C69DDE2Adofexchmbx01f_
Content-Type: text/plain; charset="us-ascii"
Content-Transfer-Encoding: quoted-printable
The following postponed Normal Building Power 208V/120V Shutdown is for bld=
g. 24 - all on Tuesday, August 13, 2013 from 12:01am til 6:00am is for your=
information. Any questions please contact Billy Homeyer x8-0432.
Thank you,
Jennifer M. Garland
Repair and Maintenance
4-4350
Type: Normal
Date: August 13, 2013/// Postponed til further notice
Day: Tuesday// Postponed til further notice
Time: 12:01am - 6:00am
Building(s): 24
Room(s): All
System: normal building power, access controls, computers, telephones, ligh=
ting, chilled water, heating hot water, supply vent/cooling/heating, gen ex=
haust/hood exhaust
Duration: 12:01am - 6:00am - 6 hrs
Reason:
We request bldg 24-DP1 normal 208V/120V bldg power shutdown from 12:01 AM t=
o 6 AM on Tuesday morning, August 13th, 2013 for Bennett Electric to instal=
l a 125A circuit breaker in DP1 and tie-in power for a new 24-114 computer =
power panel as part of the 24-4th floor LNS renovation project by Barr and =
Barr Builders (John Bidgood 508-686-0870). Sudy Nally 8-8010 and Jennifer C=
ombs 3-7671 are the MIT project managers.
DP1 feeds the following panels/equipment
The bldg 24-elevator
Normal power to the telephone switch room (ATS will switch to the emergency=
power)
6th floor power panels CP6-2 and CP6-3; all of 6th floor affected
Ground and 1st floor panels CP0-1 and CP1-1; Ground floor hallway outlets/l=
ighting (includes the soda and snack machines) and all of the 1st floor
24-032 panel P-032-B-1; all the 24-032 computer power
24-011 panel P-011; all the power to grad student office 011
Ground floor panel CP0-1; also serves some power in 032 suite offices and s=
ome hallway power
Effect:
Loss of all normal building power for the duration of this shutdown.
--_000_4EEA516695C10541B7CB963FF54A56AF13C69DDE2Adofexchmbx01f_
Content-Type: text/html; charset="us-ascii"
Content-Transfer-Encoding: quoted-printable
<html>
<head>
<meta http-equiv=3D"Content-Type" content=3D"text/html; charset=3Dus-ascii"=
>
<meta name=3D"Generator" content=3D"Microsoft Exchange Server">
<!-- converted from rtf -->
<style><!-- .EmailQuote { margin-left: 1pt; padding-left: 4pt; border-left:=
#800000 2px solid; } --></style>
</head>
<body>
<font face=3D"Calibri, sans-serif" size=3D"2">
<div>The following <b>postponed</b><b> </b>Normal Building Power 208V/120V =
Shutdown is for bldg. 24 - all on Tuesday, August 13, 2013 from 12:01am til=
6:00am is for your information. Any questions please contact Billy H=
omeyer x8-0432.</div>
<div> </div>
<div> </div>
<div>Thank you,</div>
<div> </div>
<div> </div>
<div>Jennifer M. Garland</div>
<div>Repair and Maintenance</div>
<div>4-4350</div>
<div> </div>
<div>Type: Normal</div>
<div>Date: August 13, 2013/// <b>Postponed til further notice</b></div>
<div>Day: Tuesday<b>// Postponed til further notice</b></div>
<div>Time: 12:01am - 6:00am</div>
<div>Building(s): 24</div>
<div>Room(s): All</div>
<div>System: normal building power, access controls, computers, telephones,=
lighting, chilled water, heating hot water, supply vent/cooling/heating, g=
en exhaust/hood exhaust</div>
<div>Duration: 12:01am - 6:00am - 6 hrs</div>
<div>Reason: </div>
<div>We request bldg 24-DP1 normal 208V/120V bldg power shutdown from 12:01=
AM to 6 AM on Tuesday morning, August 13th, 2013 for Bennett Electric to i=
nstall a 125A circuit breaker in DP1 and tie-in power for a new 24-114 comp=
uter power panel as part of the
24-4th floor LNS renovation project by Barr and Barr Builders (John Bidgood=
508-686-0870). Sudy Nally 8-8010 and Jennifer Combs 3-7671 are the MIT pro=
ject managers.</div>
<div>DP1 feeds the following panels/equipment</div>
<div> </div>
<div>The bldg 24-elevator</div>
<div> </div>
<div>Normal power to the telephone switch room (ATS will switch to the emer=
gency power) </div>
<div> </div>
<div>6th floor power panels CP6-2 and CP6-3; all of 6th floor affected</div=
>
<div> </div>
<div>Ground and 1st floor panels CP0-1 and CP1-1; Ground floor hallway outl=
ets/lighting (includes the soda and snack machines) and all of the 1st floo=
r</div>
<div> </div>
<div>24-032 panel P-032-B-1; all the 24-032 computer power</div>
<div> </div>
<div>24-011 panel P-011; all the power to grad student office 011</div>
<div> </div>
<div>Ground floor panel CP0-1; also serves some power in 032 suite offices =
and some hallway power</div>
<div> </div>
<div> </div>
<div>Effect: </div>
<div>Loss of all normal building power for the duration of this shutdown. <=