David Lesher wrote:
>
>Surge protectors can not protect you from ground differential issues.
>
>
True enough - but 10/100 Ethernet is normally isolated by the
transformer on the Ethernet transceiver. AFAIK there is not a
connection between the signal lines and ground. Isolation is 1500V for
the magnetics I checked.
Off course all bets are off when lightning strikes since the voltage
tends to be just a tad higher than 1500 volts.....
Mark Radabaugh