Jim Popovitch wrote:
>
>Was the device restarted? Was the polled interface so overloaded that
>UDP was dropped and your tool/application just happened to show a zero
>instead?
>
>
That would be no on both counts. All packets got replies and while
debugging the polling interval was fairly short. (on order of seconds)
so restart would be out of question and it repeated frequently enough
not to be a failover either.