[54553] in North American Network Operators' Group
RE: Weird networking issue.
daemon@ATHENA.MIT.EDU (Ramin K)
Tue Jan 7 17:20:08 2003
Date: Tue, 07 Jan 2003 14:17:38 -0800
To: "'nanog@merit.edu'" <nanog@merit.edu>
From: Ramin K <mr_list@netzero.net>
In-Reply-To: <Pine.LNX.4.44.0301072231080.3021-100000@uplift.swm.pp.se>
Errors-To: owner-nanog-outgoing@merit.edu
At 10:32 PM 1/7/2003 +0100, Mikael Abrahamsson wrote:
>On Tue, 7 Jan 2003 alex@pilosoft.com wrote:
> >
> > Sun's hme cards won't go full duplex even though they advertise it to
> > remote switch, causing immense headaches to anyone with Sun gear...
>
>That is just not true. I've had several Sun boxes with hme interfaces
>properly autoneg into 100/full with misc equipment, including 3548:s, and
>working properly.
>--
>Mikael Abrahamsson email: swmike@swm.pp.se
The behavior I've seen in the past is Sun gear negotiating properly when
plugged into Cisco gear that is already running. If you power cycle the
switch with the servers already attached the port will not negotiate
correctly... usually to half duplex.
Also I've seen duplex problems in the past week that caused, runts, giants,
collisions, CRCs, errors of all sorts, kernel module reloads, vlan tagging
failure, and depletion of the ozone layer. Or maybe is was reality tv that
caused that ozone thing...
Ramin