[54550] in North American Network Operators' Group
RE: Weird networking issue.
daemon@ATHENA.MIT.EDU (Mikael Abrahamsson)
Tue Jan 7 16:38:18 2003
Date: Tue, 7 Jan 2003 22:34:35 +0100 (CET)
From: Mikael Abrahamsson <swmike@swm.pp.se>
To: "'nanog@merit.edu'" <nanog@merit.edu>
In-Reply-To: <BCAAA5D64C837641A9EBB93E2A5089480A472D@ex2k01.corp.register.com>
Errors-To: owner-nanog-outgoing@merit.edu
On Tue, 7 Jan 2003, Charles Youse wrote:
> Besides, misconfigured duplex will not cause CRC errors.
Yes it will. It will cause CRC errors/RX underflows/RX frags/RX align on
one end and late collissions on the other end depending on which one is
running half duplex and which one is running full duplex.
--
Mikael Abrahamsson email: swmike@swm.pp.se