It is what telco's usually call a "dry-pair" or a "no-load pair". You only
need 1 pair (2 wires) with nothing on it. The key is that you don't want
the telco putting power on the line. If you want to use their PBX
connection I think you need 2 pairs instead of 1 though.
I just tested LRE yesterday and the setup is very easy. Assuming you have
pretty clean lines then you should have no problem getting it to work. The
2924 XL-LRE is even smart enough to reverse the wires if you get tip and
ring swapped.
Mike
_______________________________
Mike Pistone
NASA - Russian Services Group
Marshall Space Flight Center
Huntsville, AL 35806
Ph: (256) 544-2915
Em: Mike.Pistone@msfc.nasa.gov
-----Original Message-----
From: Ken Yeo [mailto:kenyeo@on-linecorp.com]
Sent: Thursday, January 31, 2002 1:56 PM
To: nanog@merit.edu
Subject: Circuit for Cisco Long Reach Ethernet
What kind of circuit I should order if I want to use Cisco Long Reach
Ethernet between two buildings that is 3000 feet?
Thanks.
Suan Jong Yeo
Network Engineer
Aurum Technology