[39718] in North American Network Operators' Group
Re: Netflow bug on 3-GE cards (Trident) in Cisco GSRs
daemon@ATHENA.MIT.EDU (Mikael Abrahamsson)
Sat Jul 21 03:38:15 2001
Date: Sat, 21 Jul 2001 09:37:36 +0200 (CEST)
From: Mikael Abrahamsson <swmike@swm.pp.se>
To: <nanog@merit.org>
In-Reply-To: <20010720153218.A19814@inet1.roisman.com>
Message-ID: <Pine.LNX.4.33.0107210936080.2352-100000@uplift.swm.pp.se>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII
Errors-To: owner-nanog-outgoing@merit.edu
On Fri, 20 Jul 2001, Dani Roisman wrote:
> Turns out you can only run netflow on the first port of a 3-GigE port
> on the current S-tract software rev. If you have been struggling with
> this as well, I'm eager to hear about it off-list.
In 12.0.15S you cannot use access-lists on subinterface on the 3GE either.
Wonder if that's a software bug too, or hardware limitation (like the MTU
difference on the 3GE compared to the 1GE).
Anyone?
--
Mikael Abrahamsson email: swmike@swm.pp.se