[29215] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: 7507 debug error

daemon@ATHENA.MIT.EDU (Ulf Zimmermann)
Wed Jun 14 20:45:38 2000

Date: Wed, 14 Jun 2000 16:50:58 -0700
From: Ulf Zimmermann <ulf@Alameda.net>
To: Marc Teichtahl <marct@ip.versatel.net>
Cc: nanog@merit.edu
Message-ID: <20000614165058.A11765@PacHell.TelcoSucks.org>
Reply-To: ulf@Alameda.net
Mime-Version: 1.0
Content-Type: text/plain; charset=us-ascii
In-Reply-To: <Pine.BSF.4.10.10006122237520.1523-100000@fank.m2.ip.versatel.net>; from marct@ip.versatel.net on Mon, Jun 12, 2000 at 10:38:35PM +0200
Errors-To: owner-nanog-outgoing@merit.edu


On Mon, Jun 12, 2000 at 10:38:35PM +0200, Marc Teichtahl wrote:
> 
> can anyone translate this for me ?
> > Jun 12 21:41:07.679 CED: %RSP-3-RESTART: cbus complex
> > Jun 12 21:41:55.996 CED: %DBUS-3-SW_NOTRDY: DBUS software not ready
> after
> > dbus_s
> > lot_enable(), elapsed 12032, status 0x48
> > -Traceback= 602A5284 602A6418 602B808C 60287EAC 602879B0 60290B18
> 6023F2CC
> > 6023F
> > 2B8
> > Jun 12 21:42:06.504 CED: %CBUS-3-CCBPTIMEOUT: CCB handover timed out,
> CCB
> > 0x5800
> > FF20, slot 0
> > -Traceback= 602BA350 602B7B98 602B8178 60287EAC 602879B0 60290B18
> 6023F2CC
> > 6023F
> > 2B8

I had the same error messages with a slave RSP card after hot swapping.
On Ciscos recommendation they sent us a new one in 2 hours and everything
worked fine again.

> 
> 
> -- 
> 
> 
> Marc Teichtahl				Manager, Data Network Engineering
> Versa(tel Telecom			NASDAQ: VRSA AEX: VERSA
> 
> US Cell: +1 650 248 7058		Dutch Cell: +31 6 21213104
> 

-- 
Regards, Ulf.

---------------------------------------------------------------------
Ulf Zimmermann, 1525 Pacific Ave., Alameda, CA-94501, #: 510-769-2936
Alameda Networks, Inc. | http://www.Alameda.net  | Fax#: 510-521-5073


home help back first fref pref prev next nref lref last post