[20704] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Frame Relay encap vis-a-vis point-to-point at UUNET

daemon@ATHENA.MIT.EDU (Eric Dean)
Fri Oct 23 12:09:18 1998

Date: Fri, 23 Oct 1998 11:48:00 -0400 (EDT)
From: Eric Dean <edean@gip.net>
To: Elvis <elvis@fallenones.org>
cc: elezar@pfrc.org, nanog@merit.edu
In-Reply-To: <Pine.GSO.3.96.981022181253.5278C-100000@pity.fallenones.org>


You could also order a larger circuit with the same FR paramters.

On Thu, 22 Oct 1998, Elvis wrote:

> > We also had some odd problems with our FR.  When the circuit was nearing
> > full congestion the LMI wouldn't get through and the cascade would react
> > by bouncing the circuit (which bounced the BGP, etc. etc.).  We finally
> > had to shutoff LMI which causes us problems any time they decide to
> > re-do the circuit for any reason....
> 
> Uhh...I think that LMI gets priority over any other data...so the PVC
> bouncing sounds like something else is causing LMI to stop flowing.  But
> maybe I am wrong.
> 
> Bill
> 
> 