Re: How to loadshare over many E1 links

daemon@ATHENA.MIT.EDU (Rich Sena)
Wed Sep 23 10:23:38 1998

Date: Wed, 23 Sep 1998 09:06:35 -0400 (EDT)
From: Rich Sena <ras@poppa.clubrich.tiac.net>
To: Phillip Vandry <vandry@Mlink.NET>
cc: Chris Cappuccio <chris@empnet.com>,
        "Martin, Christian" <CMartin@mercury.balink.com>,
        "'Jared Mauch'" <jared@puck.nether.net>,
        "'Scott Whyte'" <swhyte@cisco.com>,
        "'Jesper Skriver'" <jesper@skriver.dk>,
        "'nanog@merit.edu'" <nanog@merit.edu>,
        "'tdk-backbone@t.dk'" <tdk-backbone@t.dk>
In-Reply-To: <199809181909.PAA11726@Iodine.Mlink.NET>

On Fri, 18 Sep 1998, Phillip Vandry wrote:
> But I also thought that these switches only supported FDX on the 100
> ports.

Nope I've had them FDX in 10M - on the 2916 at least.

-- 
I am nothing if not net-Q! - ras@poppa.clubrich.tiac.net