[195524] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Last Week's Canadian Fiber Cut

daemon@ATHENA.MIT.EDU (Paul Stewart)
Wed Aug 16 16:09:44 2017

X-Original-To: nanog@nanog.org
From: Paul Stewart <paul@paulstewart.org>
In-Reply-To: <CY1PR13MB06457E092C56BB7E9273686DE48D0@CY1PR13MB0645.namprd13.prod.outlook.com>
Date: Tue, 15 Aug 2017 14:36:50 -0400
To: Rod Beck <rod.beck@unitedcablecompany.com>
Cc: "nanog@nanog.org" <nanog@nanog.org>
Errors-To: nanog-bounces@nanog.org

Never really heard a lot about it  =E2=80=A6. We never lost connectivity =
to Halifax from Montreal via Hibernia - interesting topic though as we =
have a backup path that I=E2=80=99m looking to replace :)

Paul


> On Aug 15, 2017, at 1:22 PM, Rod Beck =
<rod.beck@unitedcablecompany.com> wrote:
>=20
> Did we ever get any resolution on why this was such a big outage? =
Appears there were two fiber cuts. Were the fibers damaged in the same =
conduit? Is this a collapsed ring scenario?
>=20
>=20
> =
http://www.cbc.ca/news/canada/newfoundland-labrador/concerns-about-backup-=
bell-outage-1.4239064
>=20
>=20
> Roderick Beck
>=20
> Director of Global Sales
>=20
> United Cable Company
>=20
> DRG Undersea Consulting
>=20
> Affiliate Member
>=20
> www.unitedcablecompany.com<http://www.unitedcablecompany.com>
>=20
> 85 Kir=C3=A1ly utca, 1077 Budapest
>=20
> rod.beck@unitedcablecompany.com
>=20
> 36-30-859-5144
>=20
>=20
> [1467221477350_image005.png]


home help back first fref pref prev next nref lref last post