[191094] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Arista unqualified SFP

daemon@ATHENA.MIT.EDU (Tim Jackson)
Thu Aug 18 03:45:07 2016

X-Original-To: nanog@nanog.org
In-Reply-To: <dd9548a4e356d832934699fb72544efa@nek0.net>
From: Tim Jackson <jackson.tim@gmail.com>
Date: Wed, 17 Aug 2016 14:57:24 -0500
To: Stanislaw <me@nek0.net>
Cc: nanog list <nanog@nanog.org>
Errors-To: nanog-bounces@nanog.org

I'd suggest bitching and moaning at your account team & support until they
give you the key to unlock them..

--
Tim

On Wed, Aug 17, 2016 at 2:50 PM, Stanislaw <me@nek0.net> wrote:

> Hi all,
> Is there a way for unlocking off-brand transceivers usage on Arista
> switches?
>
> I've got an Arista 7050QX switch with 4.14 EOS version. Then it has been
> found out that Arista switches seem to not have possibility to unlock
> off-brand xcievers usage (by some service command or so).
>
> I've patched /usr/lib/python2.7/site-packages/XcvrAgent.py, made the
> checking function bypass the actual check and it helped: ports are not in
> errdisable state anymore. But despite of xceivers are detected correctly,
> links aren't coming up (they are in notconnect state).
>
> If anyone possibly have does have a sacred knowledge of bringing
> off-branded transceivers to life on Arista switches, your help'd be very
> appreciated. Thanks.
>

home help back first fref pref prev next nref lref last post