On 03/08/2016 07:30 AM, greg whynott wrote:
> I'd like to purchase a IP to
> Serial port device I can use for each location in the event I lock myself
> out. The requirement would be an Ethernet port, a serial port, and SSH.
I've used Cisco 2500 routers for this type of service, using the AUX
port and a roll-over cable to connect to the target device. I'm talking
2501s mostly, not the 2511 or 2508, unless you need to control more than
one device at a specific location.
Ethernet, AUX port, SSH, firewall. Updates are sketchy, but these are
mature devices.