[181274] in North American Network Operators' Group
Re: Ghosts in our 6 New Ubiquity Pros - provision issues.
daemon@ATHENA.MIT.EDU (charles@thefnf.org)
Fri Jun 19 14:25:43 2015
X-Original-To: nanog@nanog.org
Date: Fri, 19 Jun 2015 13:23:20 -0500
From: charles@thefnf.org
To: bob@fiberinternetcenter.com
In-Reply-To: <6bd2a2ff38c562392fd481154f83effc.squirrel@66.201.44.180>
Cc: nanog@nanog.org
Errors-To: nanog-bounces@nanog.org
On 2015-06-19 11:57, Bob Evans wrote:
> Thank You Charles,
> Been on NANOG a while - all the basic stuff we know well. Like, cables,
> cluster occurrences etc. Looking for the UniFi specific experience. Its
> not the switches, power, cables, ports show no CRC issues etc.
>
Sure. I've seen you around. Always good to check the basics, start at
layer 1 and work up. That doesn't change, no matter how experienced a
crew is. :)
> We even setup another network with just 2 and it happens randomly - so
> its
> some code or something.
Wait... same controller? Or a different controller? Because if you can
replicate across access points and controllers then you've probably
found a bug. Well presuming you aren't fate sharing with anything else
(like switches).
Very weird.
Think I'm going to let one of the guys here login
> the the controller and see if we missed a setting in the latest code.
> NANOGs real good at having someone with specific targeted knowledge
> appear.
>
Yes it sure is.