[166461] in North American Network Operators' Group
Re: A9K-MPA-20X1GE in ASR9001
daemon@ATHENA.MIT.EDU (Nikolay Shopik)
Fri Oct 25 06:05:39 2013
Date: Fri, 25 Oct 2013 14:05:27 +0400
From: Nikolay Shopik <shopik@inblock.ru>
To: nanog@nanog.org
In-Reply-To: <0A3447A1-8B2B-470F-9959-89BB086E63F7@rferl.org>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
I don't have any GBIC/SPF inserted in it right now, it just turn off
whole module. So won't allow me even fpd upgrade.
On 25/10/13 14:02, Ray Ludendorff wrote:
>
>
> It means that you did not purchase a original Cisco GBIC for the interface ..
> Therefore it will not be TAC supported if you have problems with the interface.
> There is a command to override this error and still use the interfaces.
>
> Sent from mobile device
>
>> On Oct 25, 2013, at 11:56, "Nikolay Shopik" <shopik@inblock.ru> wrote:
>>
>> Hey, anyone had issues with A9K-MPA-20X1GE in ASR9001?
>>
>> It get disabled for us after 20 seconds finishing initialization, with
>> such message.
>>
>> %PLATFORM-SCC-2-BAD_ID_HW : Failed Identification Test in 0/130/0 [1/0]
>> The module in 0/130/0 in this router may not be a genuineCisco product.
>>
>>