RE: PDU recommendations

daemon@ATHENA.MIT.EDU (Bill Breckenridge)
Sun Jun 23 21:04:46 2013

From: Bill Breckenridge <bill@ellipticalmobilesolutions.com>
To: Petter Bruland <Petter.Bruland@allegiantair.com>, "tritran@cox.net"
 <tritran@cox.net>, shawn wilson <ag4ve.us@gmail.com>, "North American
 Network Operators Group" <nanog@nanog.org>
Date: Sun, 23 Jun 2013 21:52:05 +0000
In-Reply-To: <DC864220297BE047821E58CF67B23F6E7D10A99E@SVIEXCMB01.allegiantair.com>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org

We have switched to Chatsworth products PDU line - robust and dependable in=
 over 100 redundant installs - all outlet/environmental/SNMP and other opti=
ons well behaved with plug-ins as well tech support is easier to access/esc=
alate

Bill

-----Original Message-----
From: Petter Bruland [mailto:Petter.Bruland@allegiantair.com]=20
Sent: Sunday, June 23, 2013 3:42 PM
To: tritran@cox.net; shawn wilson; North American Network Operators Group
Subject: RE: PDU recommendations

We're replacing TrippLite with APC. Had two TrippLite SNMP/Web cards stop w=
orking at random times, and need to be reset. Pain when the datacenter is f=
ar away. On a different note TrippLite support has been super awesome.

The APC line we went with, model # escaping me at the moment, only had over=
all unit AMP load indicator. But their SNMP access is nice, for custom grap=
hs in Cacti etc, and being able to remote bounce an outlet.

We did have a few WTI, the really old ones, which did not store the config =
in flash, thus needed to be reconfigured via serial after power outage. Eve=
n with that annoyance, they had much faster response time from telnet (....=
I know, old) turning on/off outlets than either of APC or TrippLite.

-Petter

________________________________________
From: tritran@cox.net [tritran@cox.net]
Sent: Sunday, June 23, 2013 12:05 PM
To: shawn wilson; North American Network Operators Group
Subject: Re: PDU recommendations

APC is solid. Their newer line can provide outlet metering. WTI is also goo=
d...they support redundant circuits. I've seen Baytech died after just unpl=
ugging a server.
------Original Message------
From: shawn wilson
To: North American Network Operators Group
Subject: PDU recommendations
Sent: Jun 23, 2013 8:37 AM

We currently use Triplite stuff but they've got an issue where after a few =
minutes, they stop accepting new tcp connections. We're adding a new 30A ci=
rcuit and I'm thinking of going with APC (ran them in the past and never ha=
d any issues). However, I figured I'd see if there was a better brand / spe=
cific model recommendations for quality or bang / buck?

Specs: 30A 24+ port 0U, managed (with ssh), lcd use display.