[160886] in North American Network Operators' Group
Re: 10 Mbit/s problem in your network
daemon@ATHENA.MIT.EDU (joel jaeggli)
Mon Feb 18 18:08:01 2013
Date: Mon, 18 Feb 2013 15:07:41 -0800
From: joel jaeggli <joelja@bogus.com>
To: Owen DeLong <owen@delong.com>, Mikael Abrahamsson <swmike@swm.pp.se>
In-Reply-To: <385A965A-09A7-4818-BCBF-810448D91AD6@delong.com>
Cc: NANOG <nanog@nanog.org>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
On 2/18/13 1:42 AM, Owen DeLong wrote:
> On Feb 17, 2013, at 21:12 , Mikael Abrahamsson <swmike@swm.pp.se> wrote:
>
>> On Sun, 17 Feb 2013, Owen DeLong wrote:
>>
>>> Greater attenuation is an oversimplification.
Along some dimensions sure, e.g. we have quite a lot of parameters we
can fiddle with.
With respect to an istropic raditor and the same power level it is not.
It's about 6-7dB depending on which end of the bands we're comparing -
e.g. friis trasmission equation.