[160280] in North American Network Operators' Group
Re: Rollup: Small City Municipal Broadband
daemon@ATHENA.MIT.EDU (Leo Bicknell)
Sun Feb 3 11:59:04 2013
Date: Sun, 3 Feb 2013 08:58:50 -0800
From: Leo Bicknell <bicknell@ufp.org>
To: nanog@nanog.org
Mail-Followup-To: nanog@nanog.org
In-Reply-To: <510DF096.60907@vaxination.ca>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
--zhXaljGHf11kAtnf
Content-Type: text/plain; charset=us-ascii
Content-Disposition: inline
Content-Transfer-Encoding: quoted-printable
In a message written on Sun, Feb 03, 2013 at 12:07:34AM -0500, Jean-Francoi=
s Mezei wrote:
> When municipality does the buildout, does it just pass homes, or does it
> actually connect every home ?
I would argue, in a pure dark muni-network, the muni would run the
fiber into the prem to a patch panel, and stop at that point. I
believe for fiber it should be inside the prem, not outside. The
same would apply for both residential and commercial.
Basically when the customer (typically the service provider, but
not always) orders a loop to a customer the muni provider would
OTDR shoot it from the handoff point to the service provider to the
prem. They would be responsible for insuring a reasonable performance
of the fiber between those two end points.
The customer (again, typically the service provider) would then
plug in any CPE, be it an ONT, or ethernet SFP, or WDM mux.
Note I say typically the service provider, because I want to enable
in this model the ability for you and I, if we both have homes in
this area, to pay the same $X/month and get a patch between our two
homes. No service provider involved. If we want to stand up GigE
on it because that's cheap, wonderful. If we want to stand up
16x100GE WDM, excellent as well.
It's very similar to me to the traditional copper model used by the
ILECs. There is a demark box that terminates the outside plant and
allows the customer to connect the inside plant. The facilities
provider stops at that box (unless you pay them to do more, of
course). The provisioning process I'm advocating is substantially
similar to ordering a "dry pair" in the copper world, although perhaps
with a bit more customer service since it would be a service the muni
wants to sell!
> In any event, you still have to worry about responsability if you allow
> Service Providers to install their on ONT or whatever CPE equipment in
> homes. If they damage the fibre cable when customer unsubscribes, who is
> responsible for the costs of repair ? (consider a case where either
> homeowner or SP just cuts the fibre as it comes out of wall when taking
> the ONT out to be returned to the SP.
The box is the demark. If they damage something on the customer
side, that's their own issue. If the damage something on the
facilities provider side, the facilities provider will charge them
to fix it.
There would be no "just coming out of the wall". There would be a 6-12
SC (FC?) connector patch panel in a small plastic enclosure, with the
outside plant properly secured (conduit, in the wall, etc) and not
exposed. The homewowner or their service provider would plug into that
patch panel.
--=20
Leo Bicknell - bicknell@ufp.org - CCIE 3440
PGP keys at http://www.ufp.org/~bicknell/
--zhXaljGHf11kAtnf
Content-Type: application/pgp-signature
Content-Disposition: inline
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v2.0.18 (FreeBSD)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=86sN
-----END PGP SIGNATURE-----
--zhXaljGHf11kAtnf--