On Wed, Jan 25, 2012 at 2:26 PM, jon Heise <jon@smugmug.com> wrote:
> we are moving a router between 2 data centers and we only have LX sfp's for connection, is there any issue using LX sfp's in a short range deployment ?
A Cisco 1000BASE-LX optic has the following spec:
http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6577/product_data_sheet0900aecd8033f885.html
-3dBm maximum transmit power, -3dBm maximum receive. That means you
can run it over any length. (We use LX for everything.)
--