[147272] in North American Network Operators' Group
Re: Writable SNMP
daemon@ATHENA.MIT.EDU (Jethro R Binks)
Tue Dec 6 14:57:38 2011
Date: Tue, 6 Dec 2011 19:56:38 +0000 (GMT)
From: Jethro R Binks <jethro.binks@strath.ac.uk>
To: NANOG <nanog@nanog.org>
In-Reply-To: <CAPWAtbJubOh2vszRuOro=aYUiJe1KKQopgO1HHHPXGzznZznNg@mail.gmail.com>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
This message is in MIME format. The first part should be readable text,
while the remaining parts are likely unreadable without MIME-aware tools.
--487495900-583348391-1323201398=:89376
Content-Type: TEXT/PLAIN; charset=ISO-8859-1
Content-Transfer-Encoding: 8BIT
On Tue, 6 Dec 2011, Jeff Wheeler wrote:
> On Tue, Dec 6, 2011 at 11:07 AM, Keegan Holley
> <keegan.holley@sungard.com> wrote:
> > For a few years now I been wondering why more networks do not use writable
> > SNMP. Most automation solutions actually script a login to the various
>
...
> Juniper does not support writing via SNMP. I am glad. Hopefully that
> is the first step toward not supporting SNMP at all.
So what are the alternatives these days then for automation or batch
operations?
clogin etc from shrubbery's rancid?
Net::Appliance::Session
... ?
. . . . . . . . . . . . . . . . . . . . . . . . .
Jethro R Binks, Network Manager,
Information Services Directorate, University Of Strathclyde, Glasgow, UK
The University of Strathclyde is a charitable body, registered in
Scotland, number SC015263.
--487495900-583348391-1323201398=:89376--