[140933] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: AT&T Opti-man Dallas down

daemon@ATHENA.MIT.EDU (Nikos Mouat)
Wed May 25 13:15:04 2011

Date: Wed, 25 May 2011 10:14:51 -0700 (PDT)
From: Nikos Mouat <nikm@cyberflunk.com>
To: Tim Connolly <tim.connolly@farecompare.com>
In-Reply-To: <D72BE7D8-3628-4E8B-8E45-FF9B2E74CB1F@farecompare.com>
Cc: Nanog <nanog@nanog.org>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org


Yes, we lost all our Opteman circuits in Dallas from roughly 8:30AM to 
10:30AM Central. The cause communicated to us from AT&T was:

"the router took a hit and the SUP Card failed which resulted in our outage"

our Opteman circuits in Houston were not impacted.

Nikos


On Wed, 25 May 2011, Tim Connolly wrote:

> 	The Dallas area had a round of storms go through last night. Looks 
> like this morning's flaming bag on the front porch was AT&T's "OptiMan" 
> metro-E service was down. Can anyone confirm that this was a wide outage 
> and not just a single customer? Any details released?
>
>