[132153] in North American Network Operators' Group
RE: Outage between GBLX and HE?
daemon@ATHENA.MIT.EDU (Paul Kelly :: Blacknight)
Wed Nov 17 04:21:54 2010
From: "Paul Kelly :: Blacknight" <paul@blacknight.com>
To: 'Brielle Bruns' <bruns@2mbit.com>, NANOG list <nanog@nanog.org>
Date: Wed, 17 Nov 2010 09:20:40 +0000
In-Reply-To: <4CE34CCC.6000605@2mbit.com>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
It looks like it's back now. I was seeing spotting US connectivity via GLBX=
upto 08:57 GMT.
-----Original Message-----
From: Brielle Bruns [mailto:bruns@2mbit.com]=20
Sent: 17 November 2010 03:32
To: NANOG list
Subject: Outage between GBLX and HE?
Hey All,
Sorry to bother the list, but I'm noticing that I've got no connectivity to=
Hurricane Electric through GBLX from my Qwest DSL.
In this case, I'm trying to get to tunnelbroker.net:
...
3 184-99-65-41.boid.qwest.net (184.99.65.41) 38.438 ms 49.250 ms
38.459 ms
4 sea-brdr-02.inet.qwest.net (67.14.41.14) 60.071 ms 53.198 ms
54.223 ms
5 te8-3-10g.ar5.sea1.gblx.net (64.208.110.141) 294.182 ms 437.842 ms *
6 * * *
Testing out through the T1 which goes via twtelecom works fine, as does fro=
m co-loc in Seattle which goes through Integra.
Don't suppose anyone else is noticing this as well?
--
Brielle Bruns
The Summit Open Source Development Group
http://www.sosdg.org / http://www.ahbl.org