[129052] in North American Network Operators' Group
Re: Tagged vlan inside isolated pvlan
daemon@ATHENA.MIT.EDU (David Freedman)
Tue Aug 24 10:11:22 2010
To: nanog@nanog.org
From: David Freedman <david.freedman@uk.clara.net>
Date: Tue, 24 Aug 2010 15:11:03 +0100
X-Complaints-To: usenet@dough.gmane.org
In-Reply-To: <d29f5b0f386ba376777f503642def013.squirrel@box340.bluehost.com>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
>sfouant@shortestpathfirst.net wrote:
>> Hello,
>>
>> I have a catalyst 6503 with sup32 and was trying to set a tagged vlan
>> inside a pvlan. Basically I wanna have the behavior of:
>>
>> switchport mode access
>> switchport access vlan 101
>> switchport protected.
>>
>> So that other machines connected to the 6503 won't be able to
>> communicate with this port (apart from the uplink) and in the same time
>> I want to have vlan 101 tagged in the isolated port.
>
> Check out
> http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.2/31sga/configuration/guide/pvlans.html#wp1130380
> for more information on configuring PVLANs for trunking.
Not on 6500 I'm afraid, the featureset on everything else compared to
cat4k/nexxus is quite crippled, you'll find lots of important things
missing on 6500 in PVLAN that are down to I believe hardware limitations.
Dave