[117709] in North American Network Operators' Group
daemon@ATHENA.MIT.EDU (Michael Ruiz)
Thu Sep 24 20:01:57 2009
Date: Thu, 24 Sep 2009 18:57:55 -0500
From: "Michael Ruiz" <mruiz@telwestservices.com>
To: <nanog@nanog.org>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
I found the issue. I found that one of the techs had applied the
service-policy against an interface that is on the 6-CT3 line card.
This caused the error I found. I took out the service policy applied
and applied the tx-cos command and problem fixed.=20
=20
=20
Michael Ruiz mruiz@telwestservices.com