On May 11, 2009, at 4:48 PM, Duane Waddle wrote:

> On Mon, May 11, 2009 at 3:39 PM, Mikael Abrahamsson  
> <swmike@swm.pp.se> wrote:
>>
> IIRC, you can turn the feature off WHEN it makes an issue.
>
Fixed that for you.

S550 attached to a 6509, Dell blade in a blade chassis with Power  
connect switches cross-connected to the 6509 in trunking mode.  Got  
nothing but errors, discards, and slow performance across the link  
(only to the NAS....everything else was fine).  Changed the S550 into  
redundancy mode (one NIC in standby rather than active/active) and  
everything is just peachy.  I don't have the time or inclination to  
figure out why.....I just expect these things to work when the  
manufacturer says they will.

Of course, I already have a huge issue with NetApp considering the  
EOLed a 3 month old piece of gear two months after I bought it.