[114213] in North American Network Operators' Group
RE: DSX cross-connect solution
daemon@ATHENA.MIT.EDU (Frank Bulk)
Mon May 4 16:09:40 2009
From: "Frank Bulk" <frnkblk@iname.com>
To: "'sjk'" <sjk@sleepycatz.com>,
<nanog@nanog.org>
In-Reply-To: <49FF483A.4040508@sleepycatz.com>
Date: Mon, 4 May 2009 15:07:36 -0500
Reply-To: frnkblk@iname.com
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org
We use the ADC D1M-1A0019, happily:
http://www.launch3telecom.com/adc/dsxpanels/D1M-1A0019.html
Frank
-----Original Message-----
From: sjk [mailto:sjk@sleepycatz.com]
Sent: Monday, May 04, 2009 2:56 PM
To: nanog@nanog.org
Subject: DSX cross-connect solution
I am trying to find hardware for a rebuild of our DS1 cross-connect
frame and can't seem to find much out there. We've got ~300 DS1s that
need to be x-connected between our M13s and I'm seeking an easy to
manage solution. I've looked at the Telect panels but I'm concerned that
my staff can't deal with wirewrap terminations. Has anyone seen, simply,
a high density 66 field that can fit in a 23" rack?
TIA -- steve