[113231] in North American Network Operators' Group

home help back first fref pref prev next nref lref last post

Re: Verizon EVDO Issues

daemon@ATHENA.MIT.EDU (Charles Wyble)
Wed Apr 8 16:46:08 2009

Date: Wed, 08 Apr 2009 13:40:00 -0700
From: Charles Wyble <charles@thewybles.com>
To: "nanog@nanog.org" <nanog@nanog.org>
In-Reply-To: <49DBC140.1040805@thewybles.com>
Errors-To: nanog-bounces+nanog.discuss=bloom-picayune.mit.edu@nanog.org

Update...


First, thank you to all who replied off list. The general summary of the 
offlist replies, is that a PRL update may be needed. This of course 
doesn't appear doable via Linux, and our vendor (IRG) swore up and down 
this wouldn't be required.

We had the tech remove the USB dongle (model 720) from the system and 
place it in his laptop. Came up and worked fine once vzaccess twiddled 
whatever bits it needed to.





Charles Wyble wrote:
> Been troubleshooting a very strange problem for a couple of weeks now.
> 
> I have a few hundred systems deployed throughout the United States 
> utilizing EVDO connectivity with Verizon as a carrier. They are stationary.
> 
> Over the past few weeks clusters of them in SF and Lewisville TX and a 
> few other areas have been failing intermittently. They are offline for 
> several days, then online for a few days then go offline again. They are 
> running Linux and PPPD.
> 
> Has anyone else seen anything like this? I realize that there are very 
> few other organizations with a network footprint like ours (few hundred 
> static EVDO cards). Other large users like FedEx and Amtrak aren't 
> reporting any issues. Verizon wants to replace the cards, but that 
> doesn't seem like a viable solution, as it's localized to a few areas 
> and is intermittent.
> 
> Replies on or off list appreciated.
> 
> 


home help back first fref pref prev next nref lref last post