New Sym53c8xx 1.2 driver has trouble in single ended mode (with 53c895)

daemon@ATHENA.MIT.EDU (D. Lance Robinson)
Wed Feb 17 18:03:54 1999

Date:	Wed, 17 Feb 1999 14:52:38 -0700
From: "D. Lance Robinson" <lancer@airways.com>
Reply-To: lancer@airways.com
To: linux-scsi <linux-scsi@vger.rutgers.edu>,
	Gerard Roudier <groudier@club-internet.fr>

Gerard,

The version 1.2 driver for the 53c896 seems to have problem dealing with
bus-mode changes and in particular, with single-ended devices. I am
getting a message...

     ncr53c895-1: unknown interrupts(s) ignored, ISTAT-0x22 DSTAT=0x0
SIST=0x1000

with other messages, but it continually goes into a reset cycle and does
not give up. If I remove the single-ended device from the bus, the
driver returns to normal.

I have tried different combinations and it points to my single-ended
device. I have two controllers, they both work fine with the LVD
devices, but they both fail with the single-ended device (dds-3 tape
unit) attached.

Have you seen this problem?

<>< Lance.

-