[74470] in Hotline Meeting
re: Case # 540923
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Tue Mar 30 17:45:21 2004
Message-Id: <200403302244.i2UMixKk004896@killer.mit.edu>
To: hotline@MIT.EDU
cc: larugsi@MIT.EDU
Date: Tue, 30 Mar 2004 17:44:59 -0500
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Akibia
84 Massachusetts Ave 257 Cedar Hill Street
Mail Stop W20-021 Marlboro,Ma 01752
Cambridge Ma. 02139 1 800 626 1661
(617) 253-1410 1 508 460 1800
Customer # 501-0040
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 3/31/04
------------
DHL# 8814001372
---------------------
RMA# 199826
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: System bd for an ultra5 (Einstein)
------------------------------------------------
Part Number: 375-0115
------------------------------
Hotline Number: 540923
---------------------------
Building and Room#: W20-575
-----------------------
Machine Type: Ultra5
-----------------------------
CPU S/N: FW02942312
----------------------------------
Hostname: W20-575-60
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: No video on monitor
------------------------------------------------------
Diags Used: tried another monitor/power cycled etc...
------------------------------------------------------
------------------------------------------------------
Resolution: Replaced the mother bd/system bd.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 3/30/04
------------