[43459] in Hotline Meeting

home help back first fref pref prev next nref lref last post

REPAIR FORM M12-182-14 SS Freeze Caper

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon May 18 19:40:23 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Mon, 18 May 1998 19:40:19 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
1 Amherst St                            257 Cederhill St
Mail Stop E40-334                       Marlboro, Ma 01752
Cambridge, Ma 02139                     1 800 626 1661
Customer Number = 100116                1 508 460 1800

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   5/18/98
              ------------
DHL#   8552635523
     ---------------------
RMA#   328621
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   32 meg simm & a 150 watt pwr supply for a Sparc4
                  ------------------------------------------------
Part Number:   501-2471 & 300-1279-02
             ------------------------------
Hotline Number:   5272
                ---------------------------
Building and Room#:   12-182
                    -----------------------
Machine Type:   Sparc4
              -----------------------------
CPU S/N:   630F01EA
         ----------------------------------
Hostname:   M12-182-14
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     system habgs/freezes/ & encounters physical address memory
            ------------------------------------------------------
Diags Used:   errors under Solaris 2.5.1. with Athena 8.1. Have replaced the 
            ------------------------------------------------------
              50 watt pwr supply with the 150 watt one, and have also 
            ------------------------------------------------------
Resolution:   replaced the defective 32 meg simm.
            ------------------------------------------------------
Comments:     Believe that the 50 watt pwr supply has directly affected the
            ------------------------------------------------------
              simm.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------
Date:  5//18/98
      ------------