[43386] in Hotline Meeting
Re: Possible Drop Problem in 1-245.
daemon@ATHENA.MIT.EDU (Andrew Bonvie)
Fri May 15 09:49:56 1998
In-Reply-To: <199805142034.QAA05201@paddington.MIT.EDU>
Date: Fri, 15 May 1998 09:44:31 -0400
To: "Ron M. Hoffmann" <hoffmann@MIT.EDU>
From: Andrew Bonvie <abonvie@MIT.EDU>
Cc: larugsi@MIT.EDU, hotline@MIT.EDU, network@MIT.EDU, trans-trb@MIT.EDU
The drop was moved from port 9, board 3 on E158 to port 8, board 7 on E369.
I then tested the workstation and was able to log on.
I was able to send and receive packets yesterday when pinging mit.edu and
just assumed it was the transceiver. All is well now.
Andrew
>I just went over with Lou to recheck things since the
>drop still isn't working.
>
>It appears there is receive data at the jack-end but
>no link at the hub (E158/7/2 according to the DB).
>
>Could you look into this?
>
>-Ron