REPAIR FORM M56-129-19 (SS4 Freeze Caper)

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon Apr 13 19:00:46 1998

To: hotline@MIT.EDU
Cc: wdc@MIT.EDU, larugsi@MIT.EDU
Date: Mon, 13 Apr 1998 19:00:42 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>

MIT                                     Polaris
1 Amherst St                            257 Cederhill St
Mail Stop E40-334                       Marlboro, Ma 01752
Cambridge, Ma 02139                     1 800 626 1661
Customer Number = 100116                1 508 460 1800

                   MIT CAMPUS AGREEMENT REPAIR FORM
                   --------------------------------
Date Shipped:   4/14/98
              ------------
DHL#   8552635276
     ---------------------
RMA#   323994
     ---------------------
Sales#   
       -------------------
PO#   
    ----------------------
Date Received:   
               -----------
******************************************************************
Part Description:   150 watt pwr supply & a 32 mmeg simm for a Sparc4
                  ------------------------------------------------
Part Number:   300-1279-02 & 501-2471
             ------------------------------
Hotline Number:   4141
                ---------------------------
Building and Room#:   56-129
                    -----------------------
Machine Type:   Sparc4
              -----------------------------
CPU S/N:   628F0AEE
         ----------------------------------
Hostname:   M56-129-19
          -----------------
******************************************************************
Repair Information:
------------------
Symptoms:     System freezes/hangs/& constant reboots under Solaris 2.5.1
            ------------------------------------------------------
Diags Used:   with Athena 8.1. Have replaced the 50 watt pwr supply with the
            ------------------------------------------------------
              150 one, and have replaced the defective 32 meg simm.
            ------------------------------------------------------
Resolution:   Please see Sun FCO on this issue..
            ------------------------------------------------------
Comments:     Believe that the 50 watt pwr supply has taken out the 32 meg
            ------------------------------------------------------
              simm.
            ------------------------------------------------------
Repaired By:   L.A.I.
             ------------------