[41354] in Hotline Meeting
REPAIR FORM M2-132-1
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Mon Jan 5 15:32:43 1998
To: hotline@MIT.EDU
Date: Mon, 05 Jan 1998 15:32:39 EST
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 1/6/98
------------
DHL# 7537142771
---------------------
RMA# 308744
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: 170mhz system bd for a Sparc5
------------------------------------------------
Part Number: 501-3059
------------------------------
Hotline Number: 1004
---------------------------
Building and Room#: 2-132 Classroom
-----------------------
Machine Type: Sparc5
-----------------------------
CPU S/N: 725C0009
----------------------------------
Hostname: M2-132-1
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: White Brightness on the crt. NO graphics.
------------------------------------------------------
Diags Used: Checked all connections & monitor & video bd. All o.k.
------------------------------------------------------
------------------------------------------------------
Resolution: Replaced the system bd. System now back up and operational.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 1/5/98
------------