[39780] in Hotline Meeting
(9247) M38-370-12 repair form
daemon@ATHENA.MIT.EDU (Chris J Pontier)
Fri Sep 26 11:37:10 1997
To: hotline@MIT.EDU, larugsi@MIT.EDU
Cc: cpontier@MIT.EDU
Date: Fri, 26 Sep 1997 11:37:03 EDT
From: Chris J Pontier <cpontier@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 9-26-97
------------
DHL# 7537142550
---------------------
RMA# 294988
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: 32 meg Simm
------------------------------------------------
Part Number: 5012471
------------------------------
Hotline Number: 9247
---------------------------
Building and Room#: M38-370
-----------------------
Machine Type: SPARC4
-----------------------------
CPU S/N: 628F0B0F
----------------------------------
Hostname: M37-370-12
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Level 15 interupt
------------------------------------------------------
Diags Used: Replaced Memory
------------------------------------------------------
------------------------------------------------------
Resolution: Fixed
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: Chris..
------------------
Date: 9-26-97
------------