[38313] in Hotline Meeting
REPAIR FORM M56-129-15
daemon@ATHENA.MIT.EDU (larugsi@MIT.EDU)
Mon May 12 21:05:13 1997
From: larugsi@MIT.EDU
To: hotline@MIT.EDU
Date: Mon, 12 May 1997 19:15:28 EDT
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 5/13/97
------------
DHL# 8210245131
---------------------
RMA# 277140
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: system bd 110 mhz for a Sparc4
------------------------------------------------
Part Number: 501-3134
------------------------------
Hotline Number: 5131
---------------------------
Building and Room#: 56-129
-----------------------
Machine Type: Sparc4
-----------------------------
CPU S/N: 628F0AF9
----------------------------------
Hostname: M56-129-15
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: No display on crt. Checked all power connection, and another
------------------------------------------------------
Diags Used: monitor. Still no change.
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the system bd under sun self maint.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 5/12/97
------------