[33622] in Hotline Meeting
REPAIR FORM STAGE5
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Tue May 21 18:35:09 1996
To: hotline@MIT.EDU
Cc: joewelch@MIT.EDU, larugsi@MIT.EDU
Date: Tue, 21 May 1996 18:34:59 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Polaris
1 Amherst St 257 Cederhill St
Mail Stop E40-334 Marlboro, Ma 01752
Cambridge, Ma 02139 1 800 626 1661
Customer Number = 100116 1 508 460 1800
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 5/22/96
------------
DHL# 8210243613
---------------------
RMA# 234724
---------------------
Sales#
-------------------
PO#
----------------------
Date Received:
-----------
******************************************************************
Part Description: I/O Board (Classic)
------------------------------------------------
Part Number: 501-2269
------------------------------
Hotline Number: 5256
---------------------------
Building and Room#: E40-014B
-----------------------
Machine Type: Classic
-----------------------------
CPU S/N: 335F0293
----------------------------------
Hostname: Stage5
-----------------
******************************************************************
Repair Information:
------------------
Symptoms: Monitor keeps dropping to power save.
------------------------------------------------------
Diags Used: Have checked monitor & sys.board. All o.k.
------------------------------------------------------
------------------------------------------------------
Resolution: Have replaced the I/O board under Sun self maint.
------------------------------------------------------
Comments:
------------------------------------------------------
------------------------------------------------------
Repaired By: L.A.I.
------------------
Date: 5/21/96
------------