[33619] in Hotline Meeting

home help back first fref pref prev next nref lref last post

E40-014B Stage5

daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Tue May 21 18:19:09 1996

To: hotline@MIT.EDU
Date: Tue, 21 May 1996 18:19:06 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>

Joe Welch had reported this system with monitor problems. Monitor kept jumpimg
over to power save mode. This Classic was troubleshooted down to a faulty
IO board. Have replaced IO board under Sun self maint.

Title # (5256)
SysName:  Stage5 (Classic)
S/N    :  335F0293
RMA #  :  234724
Location: E40-014B
Have forwarded to Joe.
                     --Lou  5/21/96

home help back first fref pref prev next nref lref last post