[29710] in Hotline Meeting
REPAIR FORM M1-142-12
daemon@ATHENA.MIT.EDU (Louis A. Isgur)
Thu Aug 31 22:05:35 1995
To: hotline@MIT.EDU
Cc: joewelch@MIT.EDU, larugsi@MIT.EDU
Date: Thu, 31 Aug 1995 22:05:26 EDT
From: "Louis A. Isgur" <larugsi@MIT.EDU>
MIT Digital Equipment Corp
1 Amherst St 932 Maple St Rt127
Cambridge, Ma 02139 Dock Door D001
Mail Stop e40-334 Contoocook, NH 03229-3373
Master Agreement # CS243 Att: RA# CS243
MIT CAMPUS AGREEMENT REPAIR FORM
--------------------------------
Date Shipped: 9/1/95
------------
DHL# 7975865833
---------------------
Date Received:
------------
******************************************************************
Part Description: DS5000/25 color monitor
-----------------------------------------------
Part Number: VRC16-CA
---------------------------
Hotline Number: 8342
-------------
Building and Room#: 1-142
----------------------
Machine Type: DS5000/25
----------------------------
CPU S/N: AB22409ZSI
------------------------
Hostname: M1-142-12
-----------------------
******************************************************************
Repair Information:
------------------
Symptoms: Monitor briefly flashes display on and off
-----------------------------------------------------
Diags Used: Have tested triac color cable ansd system bd.
-----------------------------------------------------
-----------------------------------------------------
Resolution: Replaced bad monitor under CSA
-----------------------------------------------------
Comments:
----------------------------------------------------
----------------------------------------------------
Repaired By: L.A.I.
-------------------------
Date: 8/31/95
------------